event_availableTiempo de entrega1 a 2 días hábiles
Entrega por DHL Express
search
CBEG-LCN Cartridge Sun Hydraulics
$8,935.29-15%
$7,637.00
IVA incluido
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure. Turn adjustment clockwise to decrease setting and release load. Full clockwise setting is less than 200 psi (14 bar). Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure. Reseat exceeds 85%
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure. Turn adjustment clockwise to decrease setting and release load. Full clockwise setting is less than 200 psi (14 bar). Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure. Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages. Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals. Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit. Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern. This valve does not have positive seals on the pilot section and will pass up to 2 in_/min.@1000 psi (32 cc/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies. All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
A1459
100 Artículos
Nuevo
Opiniones de clientes
4.4/5Basado en 5 opiniones verificadas
L
Luis G.Compra verificada
06/05/2026
Servicio impecable
El producto cumple con lo que describen. El seguimiento de la compra fue puntual.
D
Diana R.Compra verificada
17/04/2026
Cumple lo que promete
Llevo usando el producto hace un mes y cumplió con todas mis expectativas. Muy contento con la compra.
C
Claudia G.Compra verificada
09/03/2026
Producto recomendable
Volveré a comprar en Grupo Universo. La presentación del producto y el servicio fueron correctos.
O
Olga R.Compra verificada
20/12/2025
Producto de primera
El producto es muy confiable. Lo uso en el trabajo sin problemas.
E
Elena R.Compra verificada
31/05/2025
Buena experiencia
El producto resolvió lo que necesitaba en mi negocio. Resultó muy útil.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure. Turn adjustment clockwise to decrease setting and release load. Full clockwise setting is less than 200 psi (14 bar). Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure. Reseat exceeds 85%