event_availableTiempo de entrega1 a 2 días hábiles
Entrega por DHL Express
search
CBCG-LKV Cartridge Sun Hydraulics
$8,641.14-15%
$7,323.00
IVA incluido
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure. Turn adjustment clockwise to decrease setting and release load. Full clockwise setting is less than 200 psi (14 bar). Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure. Reseat exceeds 85%
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure. Turn adjustment clockwise to decrease setting and release load. Full clockwise setting is less than 200 psi (14 bar). Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure. Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages. Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit. Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern. This valve does not have positive seals on the pilot section and will pass up to 3 in_/min.@1000 psi (45 ml/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies. Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals. All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
A1442
100 Artículos
Nuevo
Opiniones de clientes
4.6/5Basado en 5 opiniones verificadas
V
Verónica R.Compra verificada
31/12/2025
Todo en orden
Compré el CBCG-LKV Cartridge Sun Hydraulics y la verdad superó mis expectativas. Repetiré la compra.
L
Lucía S.Compra verificada
09/12/2025
Justo como se ve
Cumple lo que dice la descripción: el CBCG-LKV Cartridge Sun Hydraulics es más que aceptable y fue justo lo que buscaba.
A
Alejandro V.Compra verificada
10/11/2025
Llegó bien empacado
Sin quejas con el CBCG-LKV Cartridge Sun Hydraulics. La entrega fue puntual, la calidad de los materiales es superior y el equipo de Grupo Universo resolvió mis dudas rápido.
A
Adrián R.Compra verificada
25/08/2025
Calidad y buen precio
Recomendado: el CBCG-LKV Cartridge Sun Hydraulics fue justo lo que buscaba. Una relación calidad-precio inmejorable.
W
Wendy R.Compra verificada
12/05/2025
Mejor de lo esperado
Buena compra. La paquetería entregó sin contratiempos y la presentación del producto es más que aceptable.
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure. Turn adjustment clockwise to decrease setting and release load. Full clockwise setting is less than 200 psi (14 bar). Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure. Reseat exceeds 85%