event_availableTiempo de entrega1 a 2 días hábiles
Entrega por DHL Express
search
CKEA-XEN Cartridge Sun Hydraulics
$10,277.80-23%
$7,906.00
IVA incluido
This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure. Provides hose break protection, prevents loads from drifting and positively locks pressurized loads. Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit. Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Co
This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure. Provides hose break protection, prevents loads from drifting and positively locks pressurized loads. Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit. Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Control options E, and P. Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves. The Delrin seat is suitable for dirty, medium pressure systems that are not subjected to high flows or temperatures. Extremely low leakage. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced. For models with manual load release control option, turn load release clockwise to release load. This 3 port pilot-to-open check valve and 3 port counterbalance valves are physically interchangeable (i.e. same cavities, same flow path for a given frame size). However, cartridge extension dimensions from the mounting surface may vary. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
A1403
100 Artículos
Nuevo
Opiniones de clientes
4.8/5Basado en 5 opiniones verificadas
C
Carmen R.Compra verificada
11/02/2026
Recomendado al 100%
Después de revisar otras tiendas, me quedé con Grupo Universo. El CKEA-XEN Cartridge Sun Hydraulics es de las mejores opciones que encontré.
M
Maribel L.Compra verificada
10/12/2025
Compra acertada
Compré el producto y la verdad superó mis expectativas. Lo recomiendo sin reservas.
N
Norma S.Compra verificada
25/11/2025
Cumple lo que promete
Llevo usando el CKEA-XEN Cartridge Sun Hydraulics recientemente y superó lo que esperaba. Muy contento con la compra.
S
Salvador E.Compra verificada
06/07/2025
Mejor de lo esperado
Pedí el producto el mes pasado y no he tenido un solo problema. Repetiré la compra.
D
Daniel R.Compra verificada
11/05/2025
Producto de primera
Llegó el CKEA-XEN Cartridge Sun Hydraulics y desde el primer uso funcionó tal como esperaba. Lo volveré a pedir.
This valve is a pilot to open check valve. It has a non-sealed pilot, a Delrin seat, and is non-vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will open the valve, allowing flow from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure. Provides hose break protection, prevents loads from drifting and positively locks pressurized loads. Standard unsealed pilot allows air trapped in the pilot line to be purged from the circuit. Optional external porting out of the hex end of the cartridge is available for external piloting. In this configuration, port 3 is blocked. See Co